Fully featured DeviceNet Master for up to 63 DeviceNet Slaves Open access via TCP/IP-based access protocol Quick access via DLL with same API as PC fieldbus cards Easy integration in embedded systems via ‘C’-based driver source code Open XML-based configuration possibility DeviceNet slave device configuration via Explicit Messaging

PRODUCT DETAILS
ProductProduct nameNHST-T100-EN/ECM
Part number1890.110
Brief descriptionEthernet LAN EtherCAT Master
Communication controllernetXnetX 100
Integrated MemoryRAM8 MB SDRAM
FLASH4 MB serial Flash
Memory cardType and sizeSD card, max. 2 GByte. SDHC- or SDXC-card type must not be used.
Power supplySupply voltage24 V DC ± 6 V
Maximum Current at 24 V (typically)130 mA
Typical power consumption3,2 W
ConnectorMini-COMBICON, 2-pin
Reverse voltage protectionyes
Requirement to the power supplyFor UL conform usage: Device shall be supplied by an isolated voltage source
Communication interface 1Communication standardEthernet
Interface type100BASE-TX or 10BASE-T, isolated
Connector2 * RJ45
Communication interface 2Communication standardEthernet
Interface type100BASE-TX or 10BASE-T, isolated
Connector1 * RJ45
Diagnostic interfaceTypeUSB
ConnectorMini-USB, 5-pin
DisplaysLED displaysSYS System status netHOST
APL Application status netHOST
RUN Communication status
ERR Communication status
LINK Link
ACT Activity
EnvironmentAmbient temperature range for operation0 … +60 °C
Humidity rangeno condensation permitted
Pollution degreeFor UL-compliant usage: Device must be used in a pollution degree 2 environment
DeviceDimensions (L x W x H)100 x 52 x 70 mm (without connector)
Weightappr. 150 g
Degree of protectionIP 20
Mountingon DIN rail EN 60715
ConfigurationConfiguration softwareSYCON.net
Ethernet Device Configuration Tool
ConformityRoHSYes
Conformance with EMC directivesCE signYes
EmissionCISPR 11 Class A
ImmunityEN 61131-2:2003