CONNECT YOUR MACHINES. KEEP YOUR EXISTING IP ADDRESSES. Access Control

🏭 CONNECT YOUR MACHINES. KEEP YOUR EXISTING IP ADDRESSES.

MOXA NAT-102 Industrial NAT & Network Access Control
Supplied by SUNDAR TECHNO SOLUTIONS, Bengaluru, India

Adding a new machine to your factory network? Connecting multiple production lines that use the same IP addresses? Bringing existing PLCs and HMIs into a central monitoring system?

These are common challenges in industrial networking—and the MOXA NAT-102 is designed to simplify machine network integration.

Sundar Techno Solutions recently supplied this compact industrial networking device. Here is how it can help factories, machine builders and system integrators.

🔹 WHAT IS NAT?

NAT stands for Network Address Translation.

It translates IP addresses as network traffic passes between a machine’s internal network and the factory’s external network.

A machine can retain its existing internal IP addresses while selected devices become accessible through different, unique addresses on the factory network.

Think of it as giving a machine device a separate “factory-facing address” while keeping its original address inside the machine.

This can reduce the need to change PLC and HMI address settings when integrating equipment into a larger network. The external network can be your plant LAN; an internet connection is not required.

🔹 WHY DO FACTORIES NEED IT?

Machine builders often use a standard network configuration across identical machines. For example, every machine may arrive with its PLC configured as 192.168.1.10.

That works while the machines operate on separate networks. However, connecting them directly to the same Ethernet network creates duplicate IP addresses.

NAT provides a way to keep these machine networks separate while making their devices accessible through unique translated addresses.

Typical uses include:
✅ Integrating newly purchased machines into an existing plant network.
✅ Connecting identical packaging or assembly machines.
✅ Retaining established PLC and HMI IP configurations.
✅ Connecting selected machine devices to SCADA or production monitoring systems.
✅ Expanding production lines with a repeatable network design.
✅ Controlling permitted traffic between machine and plant networks.

The suitability of the communication protocol and application should be checked during integration.

🔹 WHAT HAPPENS WHEN THERE IS AN IP CONFLICT?

Consider two machines:
• Machine A has a PLC at 192.168.1.10.
• Machine B also has a PLC at 192.168.1.10.

If both PLCs are connected directly to the same network segment, communication may become unreliable because the same IP address identifies two different devices.

A practical NAT arrangement keeps each machine on its own internal network, normally with a separate NAT-102 for each machine network.

Illustrative address mapping:
• Machine A: internal PLC 192.168.1.10 → factory-facing address 10.10.1.101.
• Machine B: internal PLC 192.168.1.10 → factory-facing address 10.10.1.102.

The factory monitoring system communicates with the two unique translated addresses. Both PLCs retain their original addresses inside their separate machine networks.

The translated addresses must be available and allocated as part of the plant’s network plan.

Important: NAT does not automatically repair two devices using the same IP address on the same internal LAN. Those devices must be readdressed or separated into different network segments. NAT rules must be configured correctly.

🔹 HOW MANY IP ADDRESSES CAN THE NAT-102 PROVIDE?

There are two different functions to understand:

1️⃣ NAT ADDRESS MAPPING

NAT translates existing addresses according to configured rules.

Moxa’s NAT-102 model-specific manual documents a maximum of 128 NAT policies. This is a rule limit—not a statement that the device supplies 128 IP addresses or supports exactly 128 connected devices. Capacity depends on the rule types, address ranges, traffic and installed firmware.

• 1-to-1 NAT maps an internal address to a corresponding external address.
• N-to-1 NAT allows multiple internal devices to share an external address for connections initiated from inside.
• Port forwarding directs selected incoming connections to specified internal devices and services.

2️⃣ DHCP ADDRESS ASSIGNMENT

The documented DHCP server function can assign addresses to DHCP-enabled devices on the internal LAN from a configured pool.

For example, a pool from 192.168.10.100 to 192.168.10.149 contains 50 addresses. This is an illustrative pool size, not the device’s maximum client rating.

The actual address pool must be planned around the subnet, reserved addresses, existing static devices and firmware limits. DHCP does not automatically change a PLC that is configured with a fixed IP address.

Also, two Ethernet ports do not mean only two end devices: an industrial Ethernet switch can connect multiple devices on the internal machine network.

🔹 KEY MOXA NAT-102 FEATURES

✔ Two 10/100 Mbps RJ45 Ethernet ports.
✔ Internal and external network interfaces.
✔ 1-to-1 NAT, N-to-1 NAT, port forwarding and NAT loopback.
✔ IP address, MAC address and port filtering.
✔ Auto Learning Lock for learning and restricting permitted device addresses.
✔ Secure Boot.
✔ Compact metal enclosure with DIN-rail mounting.
✔ Nominal 12/24/48 VDC power input.
✔ Standard NAT-102 operating temperature: −10°C to +60°C.

Auto Learning Lock helps build an access list from locally connected devices. It should be configured using the intended, trusted equipment.

The NAT-102-T is a separate wide-temperature model rated for −40°C to +75°C.

🔹 A REALISTIC FACTORY APPLICATION

Imagine a packaging plant adding another machine identical to its existing equipment.

Each machine has its own PLC, HMI and local Ethernet switch. The machine builder uses the same internal address scheme for every unit.

With a properly configured NAT-102 at each machine’s network boundary, the plant can give selected devices unique factory-facing addresses while retaining the internal machine configurations.

This supports a more organised approach to machine integration, central monitoring and future expansion.

Suitable application areas include packaging, automotive component manufacturing, assembly lines, food processing, pharmaceutical machinery and other Ethernet-connected production equipment.

🔹 WHY SUNDAR TECHNO SOLUTIONS?

Selecting industrial networking equipment requires understanding the application—not just matching connector types.

STS brings experience across industrial computing, industrial communication and factory automation, with a broader portfolio covering:

• Industrial panel PCs and fanless embedded computers.
• Rugged laptops and tablets.
• Industrial Ethernet switches and networking equipment.
• Protocol converters and industrial gateways.
• IIoT and edge AI hardware solutions.

Our Bengaluru team can discuss your network requirement, help with product selection and coordinate technical clarification and after-sales support.

For NAT selection, share your PLC/HMI models, existing IP addresses, network layout, communication protocols and the number of devices you want to access.

🔹 SUPPLY ACROSS INDIA

Based in Bengaluru, Sundar Techno Solutions welcomes enquiries and supply requirements from industrial customers across India, including:

Bengaluru, Mysuru, Hosur, Chennai, Coimbatore, Hyderabad, Visakhapatnam, Kochi, Thiruvananthapuram, Pune, Mumbai, Nashik, Ahmedabad, Vadodara, Surat, Delhi NCR, Noida, Gurugram, Faridabad, Jaipur, Chandigarh, Indore, Nagpur, Kolkata, Bhubaneswar and other industrial locations.

Contact us to discuss delivery and application support for your location.

📞 CONTACT SUNDAR TECHNO SOLUTIONS

Mobile / WhatsApp: +91 9482081014
WhatsApp: https://wa.me/919482081014
Email: sales@sundartechno.com

Website: https://www.sundartechno.in
Technical articles: https://www.sundartechno.com

Address: #24, 11th Cross, Ananth Nagar, Electronic City, Bengaluru – 560100, India.

📩 Planning to connect machines with duplicate IP addresses? Send STS your network layout and device details so we can discuss a suitable solution.

#SundarTechnoSolutions #STS #Moxa #NAT102 #IndustrialNAT #NetworkAddressTranslation #IndustrialNetworking #FactoryAutomation #MachineConnectivity #IPConflict #IndustrialEthernet #PLC #HMI #SCADA #NetworkSecurity #OTSecurity #IIoT #Industry40 #SmartManufacturing #MachineBuilders #SystemIntegrators #PackagingAutomation #IndustrialAutomationIndia #Bengaluru #MakeInIndiaManufacturing

MOXA NAT-102 supplier India, industrial NAT device Bengaluru, network address translation for factories, duplicate machine IP addresses, PLC IP conflict solution, machine network integration, industrial Ethernet networking, NAT gateway for PLC and HMI, industrial network access control, factory network segmentation, DIN rail NAT device, packaging machine networking, SCADA machine connectivity, industrial automation supplier India, Sundar Techno Solutions.

Leave a Reply