**Connect Inputs. Execute Logic. Control Outputs.**
An industrial computer can do more than display machine information. With a suitable PLC runtime, compatible I/O interfaces and a tested application, it can become the controller executing your machine’s logic.
The STS concept shown brings together a compact industrial box PC, OpenPLC software, a USB DAQ module with screw terminals, signal-conditioning interfaces and output drivers.
PLC means Programmable Logic Controller. OpenPLC is an open-source PLC software project developed by Autonomy Logic.
Its toolchain provides an editor for creating control programs, a compiler and a runtime that executes those programs on supported hardware. It is software—not the manufacturer of the STS computer or the illustrated DAQ module.
OpenPLC provides an open-source route. Its runtime is available under GPLv3, with a commercial licensing alternative.
Using and distributing the free version requires compliance with its licence conditions. Companies supplying controllers with proprietary software should confirm the applicable licensing route before deployment.
Download and explore the official software at:
Hardware, integration, application development and support are separate project costs.
The conversion is achieved through software and field interfaces:
The computer can then repeatedly read inputs, evaluate conditions and command outputs.
**Connecting an arbitrary USB DAQ module is not automatically plug-and-play.** The exact model, driver, operating system and OpenPLC integration must work together.
Imagine a process that fills a tank:
• A transmitter reports the liquid level.
• The controller compares it with the programmed limits.
• An output driver energises the filling valve.
• A tower light indicates the operating state.
• At the target level, the valve closes.
• A detected abnormal condition can trigger a lamp or sounder according to the program.
The PC becomes responsible for the defined control sequence. It can also support an HMI, trends and records where resources and application design permit.
It does not automatically become a safety PLC or gain guaranteed response times.
Appropriate conditioning provides the required sensor interface. Thermocouples, RTDs and current signals need different measurement arrangements.
The illustrated relay/driver bank and separate 24 VDC supply provide the output interface. USB communication does not mean the computer’s USB port powers all the connected loads.
A suitable IPC provides a practical platform for industrial installation:
A fanless design can remove a moving component, but the complete installation still needs suitable cooling and environmental protection.
USB DAQ is convenient for compact systems and accessible wiring. Its latency, disconnection recovery and electrical isolation must be evaluated against the process requirements.
Both can form part of a PC-based PLC solution.
**OpenPLC:** offers source access and a free GPL route, with a commercial alternative. It is worth evaluating for custom integration, training, R&D and suitable machine-control projects.
**CODESYS Control RTE SL:** provides a commercially licensed real-time runtime for supported Windows platforms, with communication, visualization and motion options according to the selected configuration.
Neither name guarantees compatibility with every DAQ device. Select the platform by required functions, supported drivers, measured timing, maintainability and overall project cost.
OpenPLC should not be advertised as doing everything in the CODESYS ecosystem without checking the specific requirement.
Each application requires suitable hardware and validation. Safety functions need an appropriate safety-rated architecture.
STS combines industrial computing experience with application-focused hardware selection.
Discuss your requirements with us for:
• Compact industrial PC configuration.
• USB DAQ and field-interface evaluation.
• Processor, memory, storage and connectivity selection.
• Hardware–software compatibility testing.
• Bengaluru-based after-sales support.
Integration, programming and commissioning responsibilities are defined in the project scope.
Pan-India supply enquiries are welcome from Bengaluru, Mysuru, Mangaluru, Hubballi–Dharwad, Belagavi, Tumakuru, Chennai, Hosur, Coimbatore, Hyderabad, Kochi, Pune, Mumbai, Nashik, Ahmedabad, Vadodara, Delhi NCR, Noida, Gurugram, Faridabad, Jaipur, Indore, Kolkata, Bhubaneswar and Visakhapatnam.
Installation and service arrangements are confirmed for each location and project.
**SUNDAR TECHNO SOLUTIONS**
*Poster and video illustrate a proposed configuration. Final capabilities depend on compatible drivers, signal conditioning, licensing and system validation.*
OpenPLC industrial PC India, USB DAQ SoftPLC, PC to PLC conversion, industrial box PC controller, USB data acquisition, thermocouple RTD interface, digital input output control, valve automation, test bench controller, industrial computer Bengaluru, Sundar Techno Solutions.

Leave a Reply