STS IPC AS SOFT PLC WITH CODESYS Control RTE SL

🏭 **STS IPC AS SOFT PLC WITH CODESYS Control RTE SL**
**Machine control, field-signal acquisition and operator visibility—built around an industrial computer.**
Can an industrial box PC work as a PLC?
**Yes.** With a compatible PLC runtime, supported I/O hardware and a properly engineered control application, an STS industrial embedded computer can form the processing platform for a PC-based PLC system.
The concept shown combines an **STS expansion-slot industrial PC, PCIe data-acquisition cards, shielded breakout cables and green terminal blocks** connecting the controller to real-world sensors and actuators.
🔷 **WHAT IS A SOFTPLC?**
A SoftPLC is software that performs programmable logic controller functions on suitable computing hardware.
It repeatedly:
✅ Reads inputs from connected equipment.
✅ Executes the programmed control logic.
✅ Updates outputs.
✅ Monitors operating conditions and reports faults.
For example, it can read a tank-level signal, check operating interlocks, start a pump and stop it when the target level is reached.
The PLC logic runs in a dedicated runtime environment. Installing Windows alone does not turn a computer into a PLC.
🔷 **WHAT DOES CODESYS Control RTE SL DO?**
CODESYS Control RTE SL provides the real-time PLC runtime for a compatible Windows-based industrial computer.
Its role is to execute control tasks with predictable timing on a correctly configured and validated platform.
Engineers can develop applications using familiar methods such as Ladder Diagram, Function Block Diagram and Structured Text. CODESYS also provides engineering and diagnostic tools to help develop, commission and maintain the control application.
The runtime licence, required features and I/O integration must be selected for the application.
🔷 **RECOMMENDED STS HARDWARE CONFIGURATION**
For this concept, we propose a configuration with processing headroom above the published two-core minimum:
🖥️ **Processor:** Intel Core i5-class x86 processor with at least four usable physical performance cores, subject to runtime and motherboard compatibility.
🧠 **Memory:** 16 GB RAM for the PLC application and appropriately managed supporting software.
💾 **Storage:** 256 GB industrial-grade SSD, with capacity and endurance selected for the logging workload.
🪟 **Operating system:** Licensed Windows 11 IoT Enterprise LTSC, with the exact build checked against the selected runtime release.
🔌 **Expansion:** Target configuration with four usable PCIe slots for selected DAQ/I/O cards. Slot widths, lane allocation, card dimensions, power and cooling must be confirmed.
🌐 **Networking:** Two Gigabit Ethernet ports for suitable separation of machine and plant-network connections.
🛠️ **Interfaces:** USB, serial and display connections according to the selected motherboard configuration.
⚡ **Industrial installation:** Suitable DC power input, secure mounting, thermal design and provision for power backup where required.
🔄 **Recovery features:** Watchdog and controlled application restart, with defined output behaviour during shutdown or faults.
These are recommended project specifications, not a confirmed specification sheet for every STS box PC. RAM and storage figures are our proposed sizing choices—not published CODESYS minimums. Final configuration follows application review.
For RTE deployment, processor and BIOS settings must follow CODESYS requirements, including disabling Hyper-Threading and efficiency cores where present.
🔷 **CONNECT REAL FIELD SIGNALS TO THE COMPUTER**
The illustrated arrangement uses PCIe DAQ cards inside the PC, with external high-density breakout cables connecting to terminal assemblies.
Depending on the selected cards and conditioning modules, the system can accommodate:
🌡️ **Thermocouples — T/C:** Temperature acquisition with suitable thermocouple interfaces and cold-junction compensation.
🌡️ **RTDs:** Resistance-temperature sensors such as Pt100, with suitable excitation and wiring support.
📈 **4–20 mA:** Pressure, level, flow and other process-transmitter signals.
🎚️ **0–10 V:** Analogue measurements or commands through appropriately rated input/output channels.
🔢 **Counter inputs:** Pulse counting from suitable encoders, meters or sensors.
🔘 **Digital inputs — DI:** Pushbuttons, limit switches and proximity sensors.
💡 **Digital outputs — DO:** Commands to suitable lamps, interfaces and actuator drivers.
⚙️ **Relay outputs:** Switching through appropriately rated relay modules and protection.
A matching connector alone is not enough: cable pinout, voltage, isolation and signal conditioning must suit the equipment. Passive terminal blocks provide wiring access; they do not automatically convert signals or add protection.
🔷 **WHY USE AN INDUSTRIAL PC AS SOFTPLC HARDWARE?**
**1️⃣ Expansion flexibility**
Internal I/O cards allow the hardware to be configured around the required measurements and control signals.
**2️⃣ Control and information on one platform**
An appropriately sized system can combine PLC control with an HMI, trends, reporting and data logging. Supporting applications must be tested so they do not compromise control timing.
**3️⃣ More room for application processing**
Machine calculations, test sequences, recipes and production records can benefit from PC processing and storage resources.
**4️⃣ Industrial installation options**
Suitable chassis, mounting, power arrangements and environmental specifications help match the computer to its operating location.
**5️⃣ Integration with plant systems**
The controller can exchange information with supervisory software and other systems through supported interfaces and licensed functions.
The industrial PC should be selected for its actual installation conditions—temperature, vibration, electrical environment and enclosure requirements—not simply its processor speed.
🔷 **WHY CONSIDER CODESYS?**
✔️ Familiar PLC programming methods.
✔️ A common engineering environment for application development.
✔️ Diagnostic tools that support commissioning and troubleshooting.
✔️ A choice of supported communication and visualization functions.
✔️ Application-based licensing to match the required scope.
The final system’s capabilities depend on the selected runtime version, licence, hardware drivers and application design.
**A Windows DAQ driver alone does not prove CODESYS RTE compatibility.** The card’s integration path and complete input-to-output response must be verified.
🔷 **TYPICAL APPLICATIONS**
🏭 **Special-purpose machines:** Sequencing, interlocks and production counters.
💧 **Pump and utility skids:** Level, pressure and operating-state control.
🧪 **Automated test benches:** Sensor acquisition, test sequencing, pass/fail evaluation and reporting.
⚙️ **Hydraulic and pneumatic test systems:** Pressure measurement, valve commands and test records.
🌡️ **Temperature-controlled equipment:** Multi-channel measurement and process control using suitable interfaces.
📦 **Packaging and assembly equipment:** Sensor monitoring, counting and actuator sequencing.
🔬 **R&D and laboratory automation:** Configurable I/O and repeatable experimental sequences.
Fast motion control, safety functions and demanding timing applications require their own suitable hardware, software and validation.
🔷 **WHY SUNDAR TECHNO SOLUTIONS?**
Sundar Techno Solutions brings industrial computing, embedded-system and automation experience to hardware selection.
Discuss your project with STS for:
🔹 Expansion-slot industrial computer selection.
🔹 Processor, memory, storage and interface configuration.
🔹 DAQ-card, cable and terminal-board compatibility review.
🔹 Hardware–software evaluation before deployment.
🔹 Bengaluru-based after-sales support.
🔹 Coordination with machine builders and automation integrators.
Hardware supply, runtime licensing, driver integration, PLC programming and commissioning can be defined clearly in the project quotation.
🔷 **BENGALURU-BASED, PAN-INDIA ENQUIRIES**
STS welcomes enquiries from Bengaluru, Mysuru, Mangaluru, Hubballi–Dharwad, Belagavi, Tumakuru and other Karnataka locations.
We also welcome requirements from Chennai, Coimbatore, Hosur, Hyderabad, Kochi, Thiruvananthapuram, Pune, Mumbai, Nashik, Ahmedabad, Vadodara, Surat, Delhi NCR, Noida, Gurugram, Faridabad, Jaipur, Chandigarh, Ludhiana, Lucknow, Indore, Bhopal, Kolkata, Bhubaneswar, Visakhapatnam and other industrial centres across India.
Delivery, installation and service arrangements are confirmed for each project.
📩 **PLANNING A PC-BASED PLC SYSTEM?**
Send us your I/O list, signal types, DAQ-card models, required control-cycle time and software requirements. We can then discuss a suitable STS hardware configuration.
**SUNDAR TECHNO SOLUTIONS**
📍 Bengaluru, Karnataka, India
📱 Mobile / WhatsApp: **+91 94820 81014**
💬 https://wa.me/919482081014
📧 **sales@sundartechno.com**
🌐 https://www.sundartechno.in
🌐 https://www.sundartechno.com
*Illustrative configuration. Requires compatible DAQ drivers, appropriate signal conditioning, licensed runtime and application validation. Ordinary SoftPLC control does not replace a safety-rated control system.*
STS SoftPLC industrial computer, CODESYS Control RTE SL India, industrial PC for PLC control, PCIe DAQ industrial computer, PC-based automation controller, Windows 11 IoT industrial PC, embedded box PC with expansion slots, thermocouple RTD data acquisition, 4–20 mA acquisition, 0–10 V analogue input, digital I/O control, industrial test bench computer, SoftPLC hardware Bengaluru, Sundar Techno Solutions.

Leave a Reply