HL7 Hospital Interface Computer

HL7 Hospital Interface Computer from Sundar Techno Solutions

A haematology analyser finishes a test. The haemoglobin result is on the instrument screen. How does that value reach the laboratory information system against the correct specimen, with the correct unit and test code, without someone having to type it again?

That is the application behind the STS fanless HL7 Hospital Interface Computer. Sundar Techno Solutions is preparing a Linux and Node-RED demonstration that takes a simulated instrument result through a physical RS-232 port, converts it into an HL7 v2 message and sends it over Ethernet to a test hospital receiver. A laboratory team can follow one result from the instrument connection all the way to the receiving application.

What is an HL7 interface?

HL7 stands for Health Level Seven. HL7 v2 gives healthcare software a common way to structure and exchange information. In a laboratory, an ORU^R01 observation message can carry a test result along with the patient or order identifiers, test code, value, unit and result status that the receiving system expects. One blood-count report can include several observations, such as haemoglobin, white blood cell count and platelet count, each in its own result entry.

HL7 in a nutshell: The gateway reads a record from an instrument, identifies what the fields mean, puts them into the hospital’s agreed message format and delivers the message to the application configured to receive it.

There are two different kinds of port in this process. Suppose a haematology analyser is plugged into COM1. That is the physical serial port where the STS computer receives the instrument data. The laboratory information system, or LIS, may run on a server elsewhere in the hospital. Hospital IT provides that server’s IP address and TCP port. The gateway sends the result to that destination, commonly using MLLP over TCP. The hospital chooses the destination and routing rules. HL7 defines how the receiving application can interpret the message.

Why do hospitals need this?
A hospital can have instruments from several manufacturers, bought years apart, feeding one LIS or hospital information system. One analyser may already output HL7. Another may send ASTM records or a manufacturer-specific serial format. Even two instruments measuring the same parameter may use different test codes.

A configured gateway can help the hospital:
– Reduce manual entry. Staff can review an electronically received result instead of retyping values and units from an instrument display.

– Keep the result associated with its source. The interface can carry the instrument ID, timestamp and specimen or order identifier supplied by the agreed workflow.

– Integrate existing instruments. A working analyser with a documented RS-232 output may be connected to a newer Ethernet-based laboratory system.
– Identify transmission problems. The receiver can return an acknowledgement, known as an ACK. The gateway can match it to the original message and flag a rejection or missing response for investigation. An accepted message confirms the agreed interface step; clinical review and release remain part of the hospital’s workflow.

Which instruments can connect?
The poster illustrates a haematology analyser, clinical chemistry analyser and vital signs monitor. These are examples of the equipment a hospital may want to integrate. The make, model, enabled data-export interface and available protocol documentation determine what can be connected.
Potential instrument Example data for the interface
Haematology analyser Haemoglobin, white blood cell count and platelet count
Clinical chemistry analyser Glucose, creatinine and liver enzyme results
Electrolyte or blood gas analyser Sodium, potassium, pH and other measured parameters
Coagulation analyser PT, INR and aPTT results
Vital signs monitor with a supported export interface Pulse rate, oxygen saturation, temperature and blood pressure observations

For a laboratory analyser, an important question is how the specimen barcode links to the test order. For a vital signs monitor, it is how the hospital associates the reading with the correct patient at that time. A serial port identifies the connected equipment. Patient and specimen identity must come from the hospital’s agreed workflow.
STS fanless gateway configuration
Feature Proposed configuration
Processor Intel Celeron J6412, quad-core www.intel.com
Memory and storage 8 GB RAM and 128 GB SSD
Instrument connectivity 4 × RS-232 serial ports
Wired networking 2 × Ethernet LAN ports
Wireless connectivity Wi-Fi and 4G LTE, for use according to hospital IT policy
Enclosure Fanless silver aluminium box PC with external cooling fins
Software platform Linux with Node-RED
Demonstration interface HL7 v2 observation messaging over Ethernet to a test receiver

What do Linux and Node-RED do inside the gateway?
Linux runs the computer. It provides the operating environment for the serial ports, Ethernet interfaces, storage and gateway software. For example, when an analyser sends a record through the first RS-232 connection, Linux makes that serial interface available to the application.

Node-RED runs the integration workflow. Its visual editor lets engineers connect the steps for reading a serial record, parsing the instrument’s fields, mapping the test code and units, building the outgoing message and processing the receiver’s reply. Each instrument can have its own mapping, so COM1 can serve a haematology analyser while COM2 handles a chemistry analyser with a different output format.

What will the STS demonstration show? A simulated analyser sends a fictitious specimen result into the box PC. On a separate computer, the free HAPI HL7 TestPanel acts as the hospital receiver. The audience can compare the original serial record with the result received over Ethernet, then see the acknowledgement return. A useful check for the laboratory team is to follow the same specimen ID, result value and unit on both screens.

Why STS?
Sundar Techno Solutions brings fanless industrial computing, serial communications, hardware configuration and bench testing together in Bengaluru. For a hospital or system integrator, that means the discussion can start with an actual analyser model and sample output. STS can scope the hardware, demonstrate the data path and identify the device-specific integration work before deployment.

Planning a hospital or diagnostic laboratory integration? Send STS the instrument make and model, interface manual, one anonymised sample output, and the message format expected by your LIS or HIS vendor. These details help define a meaningful demonstration and quotation.

Pan-India enquiries welcome from Bengaluru, Mysuru, Chennai, Coimbatore, Hyderabad, Visakhapatnam, Kochi, Thiruvananthapuram, Pune, Mumbai, Nashik, Ahmedabad, Vadodara, Surat, Delhi NCR, Noida, Gurugram, Kolkata, Bhubaneswar and other cities across India. STS

Sundar Techno Solutions | Bengaluru, India
📱 WhatsApp / Mobile +91 94820 81014
📧 Email sales@sundartechno.com
🌐 Website sundartechno.com Sundar Techno Solutions

HL7 gateway India, HL7 hospital interface computer, RS-232 to HL7 gateway, laboratory analyser integration, LIS interface India, hospital instrument connectivity, HL7 v2 gateway, Node-RED healthcare integration, fanless Linux box PC, four-port RS-232 industrial computer, diagnostic laboratory automation, Sundar Techno Solutions Bengaluru

#HL7 #HL7Gateway #HospitalIT #LaboratoryAutomation #LISIntegration #HospitalInformationSystem #HealthcareInteroperability #MedicalDeviceConnectivity #RS232 #NodeRED #EmbeddedLinux #FanlessPC #IndustrialComputing #SundarTechnoSolutions

Leave a Reply